Question 90 (Textile Engineering & Fibre Science)

If the maximum fluid circulating capacity of the above heat exchanger is 104 kg/hr and the required temperature of water at the outlet is 75oC, the maximum flow rate of water (kg/hr) at the outlet will be

(A)0.85 x 104
(B)1.28 x 104
(C)1.44 x 104
(D)1.67 x 104
[Show Answer]

Option D is correct.

Maximum flow rate of water x specific heat of water x temperature of water=Maximum fluid circulating capacity x specific heat of fluid x temperature of fluid

Maximum flow rate of water x 4200 x (75-30)=10^4 x 2500 x (200-75)

Maximum flow rate of water x 4200 x 45=10^4x 2500 x 125

Maximum flow rate of water =10^4 x 1.65

Maximum flow rate of water =1.65 x 10^4